HP SAS硬碟leds燈號說明

HP SAS硬碟leds燈號(hp g7/g6系統適用)說明

分享此文連結 //n.sfs.tw/10031

分享連結 HP SAS硬碟leds燈號說明@新精讚
(文章歡迎轉載,務必尊重版權註明連結來源)
2019-10-25 10:25:07 最後編修
2016-10-15 04:08:18 By 張○○
 

之前有一段時間,被我的DL380 g7前面傳出的BEEP BEEP逼逼聲困擾很久,因為很機房很吵,這聲音很小,隱約聽到,但又不確定從哪發出來。

我把頭貼在機器前面聽,似乎是從前面面板發出來的。

問題是沒有任何的故障燈啊?

過了一二個月,才發現一顆硬碟亮紅燈,把它換了就好了。

原來這硬碟還有故障前警告的功能


Note: Predictive failure alerts can occur only when the hard drive is connected to a Smart Array controller.

Online/activity
LED (green)

Fault/UID LED (amber/blue)

Interpretation

On, off, or flashing

Alternating amber and blue

The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application.

On, off, or flashing

Steadily blue

The drive is operating normally, and it has been selected by a management application.

On

Amber, flashing regularly (1 Hz)

A predictive failure alert has been received for this drive. Replace the drive as soon as possible.

On

Off

The drive is online, but it is not active currently.

Flashing regularly (1 Hz)

Amber, flashing regularly (1Hz)  

Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do
not replace the drive until the expansion or migration is complete.

Flashing regularly (1 Hz)

 Off

Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.
The drive is rebuilding, erasing, or it is part of an array that is undergoing capacity expansion or stripe migration.

Flashing irregularly

Amber, flashing regularly (1Hz)  

 The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible.

Flashing irregularly

Off

The drive is active, and it is operating normally.

 Off

Steadily amber

 A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible.

 Off

Amber, flashing regularly (1Hz)  

 A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.

 Off

 Off

 The drive is offline, a spare, or not configured as part of an array.

END

你可能感興趣的文章

HP SAS硬碟leds燈號說明 HP SAS硬碟leds燈號(hp g7/g6系統適用)說明

台灣2022(民國111年)節慶國定假日 ics下載 找不到2022年的假日ics檔?沒關係,我自己做一個

NETCRAFT發現你的網站及作業系統 NETCRAFT可以發現你的網站及作業系統

程式、函數、資料庫命名的風格 程式或資料庫自己定義統一的命名規則,可以防止因為一個拚字的錯誤花了半個小時來找,也可說是提升工作效率的關鍵。

台灣2021(民國110年)節慶國定假日 ics下載 找不到2021年的假日ics檔?沒關係,我自己做一個

HTC 10evo的相機不同ISO比較 新入手的HTC10 EVO這台1.6千萬畫素的相機,不同ISO和解析度畫質的比較

我有話要說

>>

限制:留言最高字數1000字。 限制:未登入訪客,每則留言間隔需超過10分鐘,每日最多5則留言。

訪客留言

[無留言]

隨機好文

談借錢 人借錢時手心向上頭向下,人還錢時手心向下頭向上

[jQuery] select 元件的取值及給值 html中的元件select,在jquery中要如何使用?

[HP DL380G7] 生效啟動第3,4片網卡/開啟或關閉內建的網卡 HP DL380G7 預設第3,4片網卡裝完系統後找不到,難道是壞了?要怎麼辦?

[Freebsd] 使用 ADSL 撥接上網 Freebsd上要使用 ADSL 撥接上網,該如何設定?

一個邏輯的錯誤刪了全部檔案的經驗 今天本來想做一件很簡單的事,但卻足足浪費我多一倍的時間,再加上刪掉我全部的檔案,原因只是因為我自己的邏輯錯誤。