HP SAS硬碟leds燈號說明

HP SAS硬碟leds燈號(hp g7/g6系統適用)說明

此文完整連結 http://n.sfs.tw/10031

複製連結 HP SAS硬碟leds燈號說明@新精讚
(文章歡迎轉載,務必尊重版權註明連結來源)
2017-06-16 17:30:42 最後編修
2016-10-15 04:08:18 By 張○○
 

之前有一段時間,被我的DL380 g7前面傳出的BEEP BEEP逼逼聲困擾很久,因為很機房很吵,這聲音很小,隱約聽到,但又不確定從哪發出來。

我把頭貼在機器前面聽,似乎是從前面面板發出來的。

問題是沒有任何的故障燈啊?

過了一二個月,才發現一顆硬碟亮紅燈,把它換了就好了。

原來這硬碟還有故障前警告的功能


Note: Predictive failure alerts can occur only when the hard drive is connected to a Smart Array controller.

Online/activity
LED (green)

Fault/UID LED (amber/blue)

Interpretation

On, off, or flashing

Alternating amber and blue

The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application.

On, off, or flashing

Steadily blue

The drive is operating normally, and it has been selected by a management application.

On

Amber, flashing regularly (1 Hz)

A predictive failure alert has been received for this drive. Replace the drive as soon as possible.

On

Off

The drive is online, but it is not active currently.

Flashing regularly (1 Hz)

Amber, flashing regularly (1Hz)  

Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do
not replace the drive until the expansion or migration is complete.

Flashing regularly (1 Hz)

 Off

Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.
The drive is rebuilding, erasing, or it is part of an array that is undergoing capacity expansion or stripe migration.

Flashing irregularly

Amber, flashing regularly (1Hz)  

 The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible.

Flashing irregularly

Off

The drive is active, and it is operating normally.

 Off

Steadily amber

 A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible.

 Off

Amber, flashing regularly (1Hz)  

 A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.

 Off

 Off

 The drive is offline, a spare, or not configured as part of an array.

你可能感興趣的文章

來自網路的爬蟲分析 分析最近來自網路上的爬蟲

W3C 的檢測及規範 w3c和一個Mozilla基金會提供的線上檢測w3c的網站

[Firefox] 使用Firefox一次將頁面所有圖檔下載 使用Firefox一次將頁面所有圖檔下載的3個方法

鍵盤上特殊符號及按鍵的英文及中文讀法 鍵盤上特殊符號及按鍵的英文及中文要怎麼讀?

台灣2019節慶國定假日 ics下載 找不到2019的假日檔,沒關係,我自己做一個

移除google 的頁庫存檔--移除在google中保存的網頁資料 我的網頁或文件被google保存了,但我不想給別人下載要怎麼做?

YAHOO 拒絕我的mail:spamhaus's list 有人反應yahoo收不到信,因為該ip被列入spamhaus's list

常用1200字簡體字 為了加速正簡互換的效能,我針對常見的簡體字做了挑選,花了六個小時,整理出最常用的1200個簡體中文字及正體中文字對照

好用的3+2碼郵遞區號查詢系統推薦 網路上找到用地址輸入判斷3+2碼郵遞區號的辨識率不高,除了這個網站…

看懂DSUB DVI HDMI USB等各式影音接頭 看懂DSUB DVI HDMI等各式影音接頭

我有話要說


限制:留言最高字數1000字,超過部分會被截掉。請注意:留言不可帶有網址,會被濾掉。 限制:未登入訪客,每則留言間隔需超過10分鐘,每日最多5則留言。

訪客留言

[無留言]

隨機好文

HP SAS硬碟leds燈號說明 HP SAS硬碟leds燈號(hp g7/g6系統適用)說明

[jQuery] select 元件的取值及給值 html中的元件select,在jquery中要如何使用?

[Windows7] 移除IE10及移除IE11 Windows7 不得已的情況要移除IE11或IE10怎麼做?

UTF8中文字/全形一覽 快速查詢urf-8的中文字,共計13246中文字(5401常用字+7652罕用字+日文或編號),292全形符號,27半形符號。

一個邏輯的錯誤刪了全部檔案的經驗 今天本來想做一件很簡單的事,但卻足足浪費我多一倍的時間,再加上刪掉我全部的檔案,原因只是因為我自己的邏輯錯誤。